Official Distributor of Emcee Electronics instruments (Models 1140, 1152, 1153, 1154, 1150); Falex F400 Thermal Oxidation Tester; FMS PORLA Stability Analyser. We supply Consumable Materials for Aero Engines including OMAT, COMAT, CML, SPM.
 
 
Finnish Measurement Systems

Med-Lab Limited are authorised distributors for the Finnish Measurement Systems Limited (FMS) PORLA.

The PORLA is a Fully Automatic Analyser for measuring the Stability and Compatibility of Heavy Fuel and Crude Oils.

  • ASTM Test Method D7112
  • Analyzer performs complete analytical procedure fully automatically
  • High automation level saves operator time and reduces costs
  • Sample preparation time of 5 minutes
  • Detector uses reflected light, sensitive to asphaltene particles
  • No need to filter samples to remove coke particles and other contaminants
  • Capable of analyzing oils with asphaltene content as low as 0.1%
  • Ideally suited to Visbreaking and hydrocracking processes
  • Reports the following values for each analysis performed
    o P-value
    o Solvent equivalent/flocculation ratio, FR5/1
    o Peptisability of asphaltenes, Pa
    o Peptizing power of oil medium, Po
    o FRmax
    o Xmin
    o Correlation coefficient (accuracy of result)
    o Solubility Blend Number, Sbn
    o Insolubility Number, In
  • Plots graph for quick and easy checking of result
  • Determines compatibility parameters according to Exxon Mobil blending model
    o Correlation coefficient (accuracy of result)
    o Solubility Blend Number, Sbn
    o Can be applied to blending of crude oils, marine fuel oils, etc
  • Very quick to clean detector (1 minute)
  • Desk-top laboratory analyser
  • Analyser simple to operate
  • Minimal operator time needed for sample preparation
  • Any combination of aromatic and paraffinic solvents can be used
  • Analysis performed at slightly elevated temperatures to reduce reaction time
  • 3-point titration typically takes 90 minutes
  • Clean cycle performed between each titration
  • Thorough clean cycle performed at end of each test leaving instrument ready for next analysis
  • Increased precision compared to manual and other methods - Reproducibility and Repeatability of 0.08 at P-value of 1.5
  • Results stored on PC hard drive, possible to print hard copy
  • Allows production process to operate closer to severity limit - huge cost savings possible!
  • Payback on investment in 6-8 months for time savings made on operator time
  • Payback possible in 1-2 months through greater optimisation of process
  • Installation and training, including application build-up in customer's laboratory

For further information, please contact Steve King or Mark Knight on pc@med-lab.co.uk or telephone +44 (0) 1332 349094.

Click here to go to the Finnish Measurement Systems Site

 

PORLA Automatic Crude and Heavy Fuel Oil Stability and Compatibility Analyser

 

 

 

 

PORLA Automatic Crude and Heavy Fuel Oil Stability and Compatibility Analyser

 

 

 

 

PORLA Automatic Crude and Heavy Fuel Oil Stability and Compatibility Analyser